AXIS A8207-VE – Direct calling to 2N® Indoor Touch 2.0

2N® Indoor Touch 2.0 is able to receive calls from AXIS door stations such as A8207-VE or I8016-LVE. However there are some limitations.

Limitations

  • It is not possible to make a call from the 2N® Indoor Touch 2.0 towards the AXIS Door Stations.
  • No video preview during the incoming call.
  • 2N® Indoor Touch 2.0 with firmware version 4.0.5. and later.
  • Tested with AXIS A8207-VE with firmware version 18.
  • IP address of AXIS A8207-VE: 10.0.14.70. IP address of 2N® Indoor Touch 2.0: 10.0.14.55. This is only an example, please change it according to your network requirements.

Configuration of 2N® Indoor Touch 2.0

  • Go to onscreen menu - Intercoms - Settings and disable SIP port randomisation feature

Configuration of AXIS A8207-VE or AXIS I8016-LVE intercoms

  • Go to web management - VoIP - SIP Settings and enable SIP.


  • Go to web management - VoIP - Phone book - Call button and add 2N® Indoor Touch 2.0's SIP address as a recipient of the call button press.

  • Go to web management - VoIP - DTMF and add DTMF Sequence for unlocking the door by 2N® Indoor Touch 2.0.

  • Go to web management - Events - Management - Action Rules and create a new Action Rule to open the door when DTMF sequence is received during call.