3. Technical Parameters
Supported Protocols
- LAN interface: IPv4, ARP, TCP, UDP, DHCP, ONVIF
- Device configuration: HTTP/HTTPS
- Call signalling: SIP 2.0 (UDP)
- Audio data transmission: RTP (G.711, G.729, G.722, L16/16kHz)
- Audio streaming: RTSP
- Time synchronisation: SNTP
- Auto provisioning: TFTP
- E-mail sending: SMTP
Power Supply
- External power supply: 9 to 36 V ±10 % / 2 A DC or PoE, typically 12 V DC
- PoE: 802.3af (Class 0 – up to 12.95 W)
- Power consumption: 2 W at relax
Note
- If you feed the device from a DC power source and the supply voltage is lower than 12 V, then the output voltage is limited to the supply voltage value.
LAN Interface
- LAN interface count: 1 (since HW version 568v2)
- PoE: 802.3af on LAN1 only
- Parameters: 10/100BASE-TX with Auto-MDIX, RJ-45
- Recommended cabling: Cat-5e or higher
Video Interface
- Video input count: 2 (IN1, IN2)
- Video input format: PAL or NTSC composite signal
- Camera power supply: 12 V, max 500 mA (+12 V, VGND)
Video stream
- Protocols: RTP / RTSP / HTTP
- Video call codecs: H.2663, H.263+, H.264
- ONVIF/RTSP stream codecs: H.264, MPEG4, MJPEG
- IP camera function: Yes, ONVIF v2.4 profile S compatible
Bandwidth
- Audio codecs
- PCMA, PCMU – 64 kbps (with 85.6 kbps headers)
- G.729 – 16 kbps (with 29.6 kbps headers)
- G.722 – 64 kbps (with 85.6 kbps headers)
- L16 / 16 kHz – 256 kbps (with 277.6 kbps headers)
Video codecs
Set the video codec data flows in the Services / Phone / Video menu for calls and in the Services / Streaming / RTSP menu for streaming. The set bandwidth represents the value that the codec has to approach on a long-time average. The data flows can vary depending on the scene to be scanned.
Audio Interface
- Microphone input: Standard electret microphone, Max. Vpp = 100 mV, Rin = 4,4 kΩ, Vbias = 1,5 V
- Line input: Max. 755 mV RMS, Rin = 47 kΩ
- Amplifier output: 10 W amplifier of class D, MONO output, THD < 1 %, minimum loudspeaker impedance: 4 Ω
- Line output: Max. 755 mV RMS, Rout = 600 Ω
- Acoustic echo cancelling: AEC, full duplex
Button/Keypad Interface
- Button count: Up to 16 separate buttons in 4×4 matrix
- Button function: User programmable
- Matrix outputs
- 4 (ROW1–4 terminals)
- Uout < 0.1 V (L), Uout > 3.2 V (H), up to 8 mA
- Matrix inputs
- 4 (COL1–4 terminals)
- Uin < 1.15 (L), Uin > 2.15 V, max. Uin = 5 V
LED Control Outputs
- Output count: 3 (LED1±, LED2± and LED3± terminals)
- Output function: User programmable
- Output current: Typ. 20 mA
- Output voltage: Up to 12 V
Digital Outputs
- Output count: 2 (OUT1± and OUT2± terminals)
- Output function: User programmable
- Output type: Power output with short-circuit protection
- Output voltage: 10 up to 12 V DC
- Output current: Up to 350 mA
Digital Inputs
- Input count: 2 (IN1± and IN2± terminals)
- Input function: User programmable
- Input type: Galvanically isolated inputs (opto-couplers)
- Characteristics: Uin < 1.1 V (L), Uin > 3 V (H), max. Uin = 32 V
Relay Output
- Output count: 1 (NC, NO, COM terminals)
- Output function: User programmable
- Limits (AC/DC): Up to 30 V / 1 A
Mechanical Properties
- Working temperature: −40 °C – 55 °C
- Working relative humidity: 10 % – 95 % (non-condensing)
- Storing temperature: −40 °C – 70 °C
- Dimensions
- 142 x 98 x 34 mm (Part No. 9154100)
- 138 x 90 x 26 mm (Part No. 9154101)
- Weight
- Up to 280 g (Part No. 9154100)
- Up to 150 g (Part No. 9154101)
- Protection class
- IP20 (Part No. 9154100)
- IP00 (Part No. 9154101)