4. Technical parameters

Basic technical specifications

  • Nominal power supply network voltage: 230 V or 115V
  • Power supply voltage tolerance: +/- 10 %
  • Nominal frequency: 50 Hz 
  • Input: 160 
  • Fuse: 10A
  • Recommended power backup source: –
  • External backup power source voltage: –
  • Max. backup source consumption: –
  • Typical operation time with fully charged batteries: –
  • Basic unit size: 482x133x310 mm (84HPx3U)
  • Basic unit weight: 12.5 kg
  • Extended unit size: 482x133x310 mm (84HPx3U)
  • Extended unit weight: 12.5 kg

Communication interface

LAN

  • Signals: Pin1=transit +, Pin2=transit -, Pin3= receive +, Pin6= receive -
  • Transmission speed: 10/100 Mb/s
  • Interface type: Eth T-Base 10/100

USB

  • Signály: USB -A
  • Transmission speed: 1,5 Mb/s
  • Interface type: 2xUSB v1.1

R232

  • Signals: Pin1= TxD-, Pin2= TxD+, Pin3aPin4= GND, Pin5= RxD+, Pin6= RxD-
  • Transmission speed: 115200 Bd
  • Interface type: RS 232C / 115200Bd,8bit ,parity=none, stop bit=1 

MMC

  • Signals: MMC 7pins and MMC Plus 13 pins
  • Transmission speed: up/down 18/22 Mb/s
  • Interface type: 1-bit (MMC) and 4-bit bus

Climate conditions

  • Temperature range: +5...+45 °C.
  • Relative air humidity: max. 85 % (40 °C) without condensation
  • Premises description – basic characteristics: standard premises
  • Operational position: horizontal

Internal lines

  • Analogue input impedance: 600 Ω
  • Ringing voltage
  • Line feeding voltage: 60V
  • Line current: cca 25 mA

External lines

  • Analogue input impedance: 600 Ω
  • SS voltage of closed loop at the I power =?? mA
  • Maximum loop current: 65 mA
  • SS resistance during pulse: min. 1 MΩ
  • SS resistance during interruption: max. 320 Ω
  • Earth-leakage power when hanged-up: max. 100 μA
  • Ringing impedance: 2–10 kΩ
  • Ringing voltage detection: 10–25 V

Digital system lines 

  • Input power: 48V
  • Call conduction impedance: 600 Ω
  • Number of connectible conductors: 2 

ISDN BRI

ISDN BRI S0 TE: Interface type – S0 (TE–S/T, LT–S ) – for connection to VTS

  • Protocol: DSS1 EURO ISDN with power supply
  • Interface configuration: P–MP (point – several points) – supports MSN, P–P (point – point) – supports DDI
  • Connection: 4-wires
  • Connection type: RJ 45

ISDN BRI S0 NT: Interface type – S0 (NT–S/T, LT–T) – inner S0 BUS

  • Protocol: DSS1 EURO ISDN with power supply
  • Interface configuration: P–MP (point – several points), P–P (point – point)
  • Connection: 4-wires
  • Connection type: RJ 45

ISDN PRI

  • Typ rozhraní: S0
  • Protocol: DSS1 EURO ISDN
  • Synchronisation: Master/Slave
  • Connection: 4-wires
  • Connection type: RJ 45

GSM Gateway

  • Standard GSM900/1800, phase II

  • Voice transmission: EFR, FR (enhacced full rate, full rate)
  • Receiver sensitivity: -104 dBm
  • Transmitter output: Up to 2W during pulse 
  • SMS support: TXT, PDU
  • SIM card: small , 3V
  • Antenna connection: SMA

VoIP

Specifications of the DTMF broadcasting selection:

  • Minimum/ maximum level for the assessment of the lower or higher frequency: According to Q23

Specifications of the pulse selection broadcasting:

  • Pulse duration: 60 ms
  • Interruption duration: 40 ms

Specifications of the pulse selection reception:

  • Pulse duration: 30 ms to 70ms
  • Interruption duration: 30 ms to 70ms

FLASH detection

  • FLASH broadcasting specifications: 100 ms
  • FLASH reception specifications: 80 ms...150 ms (Preset values, can not be changed)

FSK detection

  • FSK reception specifications: 40 dB
  • FSK broadcasting specifications: 40 dB

Other signal detection

  • Modem detection specifications: 1300 Hz
  • Facsimile detection specifications: 1100 Hz
  • Dial tone frequency: 425 Hz
  • Dial tone level: -7 dB
  • Busy tone frequency: 425 Hz
  • Busy tone level: -7 dB

Nominal transmission inhibition:

  • Analogue – Analogue connection: -7 dB
  • Analogue – Digital connection: -7 dB
  • Digital – Digital connection: 0 dB

Audio/IO/Rele

The rights of the producer to adjust the product specifications in order to improve the characteristics of the product as compared to the product documentation are reserved.

The product may only be used in compliance with the User's Manual and for purposes, for which the product was designed and manufactured.

After the product lifetime was terminated please dispose the product or its parts in compliance with the valid environmental protection regulations.