Make sure that the following 2N® Indoor View installation conditions are met:

  • There must be enough space for the device installation.
  • The device is designed for vertical wall mounting (perpendicular to the floor) in the height of up to 120 cm above the floor. If necessary, operate the device in a position other than as aforementioned for a short time only, for quick testing purposes in a servicing center, for example.
  • Exceeding the allowed operating temperature may not affect the device immediately but leads to premature ageing and lower reliability. For the acceptable range of operating temperatures and relative humidity values refer to S. 6. Technical Parameters.
  • The device is not designed for environments with increased vibrations such as means of transport, machine rooms and so on.
  • The device is not intended for dusty environments and places with unstable humidity and abrupt temperature changes.
  • The device may not be exposed to aggressive gas, acid vapors, solvents, etc.
  • The device is not intended for direct connection into the Internet/WAN.
  • The device must be connected to the Internet/WAN via a separating active network element (switch/router).
  • The device is designed for indoor use. It may not be exposed to rain, flowing water, condensing moisture, fog, etc.
  • The device cannot be operated on places exposed to direct sunshine and near heat sources.
  • Keep some free space above and below the device to allow air to flow and conduct heat away.
  • No strong electromagnetic radiance is allowed on the installation site.
  • Make sure that the VoIP connection is configured properly according to the SIP and other VoIP recommendations.
  • It is recommended that the power adapter be connected to the mains via a UPS and reliable overvoltage protection.

Power Supply Connection

You can feed 2N® Indoor View as follows:

  1. Use a 12 V / 1 A DC power adapter connected to the backside terminal board.
  2. Use an Ethernet cable connected to a PoE supply or PoE supporting Ethernet switch/router.

PoE Supply Connection

Use a standard straight RJ-45 terminated cable to connect 2N® Indoor View to the Ethernet. The device supports the 10BaseT and 100BaseT protocols. 

Caution

  • Factory reset results in a change of the Ethernet interface configuration!
  • A defective Ethernet cable may lead to a high packet loss in the Ethernet and subsequent instability and poor call quality!

Warning

  • Do not connect any external power supply if PoE is used and vice versa.
  • Connection of a defective or improper power supply may lead to a temporary or permanent device failure.
Ethernet cable connectorEthernet socket



Firmware Upload

We recommend you to upgrade the 2N® Indoor View firmware during installation. Refer to www.2n.com for the latest FW version. Refer to 3.2.5 System for the firmware upgrade procedure.

  • Žádné štítky