AutoCLIP Routing - How to set in 2N® VoiceBlue MAX

What is AutoCLIP?

  • The GSM gateway automatically stores information about outgoing calls to the AutoCLIP routing table. When a person calls back the call is routed directly to the original number. If original number is not available the call is routed to the next number set up in the configuration (e.g. receptionist).

How to set in 2N® VoiceBlue MAX?

  • Go to Gateway Configuration / GSM Outgoing Groups / Others and set the parameters as follows
  • Time to keep CLIP in the table – set the time duration for which records should be kept in the AutoCLIP routing table.
  • Add record only for an unconnected call – only unconnected outgoing calls (missed calls on a mobile phone) are stored in the AutoCLIP table.
  • Delete record for a connected answer – if the call back is answered, the record in the AutoCLIP table will be deleted.
  • In the AutoCLIP routing table you can see the record of the unconnected call.

  • When the user (737276015) has a missed call and returns the call, he will be directly forwarded to destination 11 as shown in the AutoCLIP routing table and also in the trace bellow.