7. Available Digital Inputs and Outputs
In this section, the digital inputs and outputs available on each 2N IP intercom model are described.
- 2N® IP Vario
- 2N® IP Force/Safety
- 2N® IP Audio/Video Kit
- 2N® IP Verso/LTE Verso
- 2N® IP Solo
- 2N® SIP Audio Converter
- 2N Access Unit
- 2N® IP Base
2N® IP Vario
Outputs
- relay1 – relay output on basic unit
- relay2 – relay output on additional switch (if installed)
- cr_relay1 – relay output 1 on card reader (if installed)
- cr_relay2 – relay output 2 on card reader (if installed)
- led_secured – red LED indicator under name tags (for display-less 9137xxxU models only)
Inputs
- cr_input1 – digital input 1 on card reader (if installed)
- cr_input2 – digital input 2 on card reader (if installed)
2N® IP Force/Safety
Outputs
- relay1 – relay output on basic unit
- output1 – active digital output on basic unit (for board version 555v3 and higher, active digital output is connected with relay output 1 in 555v2 boards)
- relay2 – relay output on additional switch (if installed)
- output2 – active digital output on additional switch (if installed)
- cr_relay1 – relay output on card reader (if installed)
- cr_output1 – active digital output on card reader (if installed)
- led_secured – red LED indicator on card reader (if installed)
- led_ringing – orange LED indicator of ringing (for models with pictograms only)
- led_connected – blue LED indicator of connected call (for models with pictograms only)
- led_door – green LED indicator of door opening (for models with pictograms only)
- led_key1 – first button backlight at Safety
- led_key2 – second button backlight at Safety
- led_key3 – third button backlight at Safety
Inputs
- tamper – tamper switch (if installed)
- cr_input1 – digit input 1 on card reader (if installed)
- cr_input2 – digital input 2 on card reader (if installed)
- input2 – digital input 2 on additional switch (if installed)
2N® IP Audio/Video Kit
Outputs
- relay1 – relay output
- output1 – digital output 1
- output2 – digital output 2
- led1 – LED 1 control output
- led2 – LED 2 control output
- led3 – LED 3 control output
Inputs
- input1 – digital input 1
- input2 – digital input 2
2N® IP Verso/LTE Verso
Basic Unit
Outputs
- output1 – digital output
- relay1 – relay output
- led_secured – red LED indicator at the panel
Inputs
- input1 – digital input on basic unit
I/0 Module
The inputs / outputs are addressed as follows: <module_name>.<input/output_name>, e.g. module5.relay1.
The module name is configured in the Module name parameter in the Hardware / Extenders menu.
Outputs
- relay1 – relay output 1
- relay2 – relay output 2
Inputs
- input1 – digital input 1
- input2 – digital input 2
- tamper – tamper switch (if installed)
Wiegand Module
The input is addressed as follows: <module_name>.<input_name>, e.g. module2.tamper
The module name is configured in the Module name parameter in the Hardware / Extenders menu.
Outputs
- output1 – output LED OUT
Inputs
- input1 – vstup LED IN
- tamper – tamper switch (if installed)
2N® IP Solo
Outputs
- output1 – digital output
- relay1 – relay output
- led_secured – red LED indicator at the panel
Inputs
- input1 – digital input on basic unit
- tamper – tamper switch
2N® SIP Audio Converter
Outputs
- relay1 – relay output
Inputs
- Unavailable
- It is possible to use Event.KeyPressed: Key=%1 for events generated at LOGIC IN input
2N Access Unit
Basic Unit
Outputs
- output1 – digital output
- relay1 – relay output
- led_secured – red LED indicator at the front panel
Inputs
- input1 – digital input No. 1 on basic unit
- input2 – digital input No. 2 on basic unit
- input3 – digital input No. 3 on basic unit
- tamper – tamper switch
I/0 Module
The inputs / outputs are addressed as follows: <module_name>.<input/output_name>, e.g. module5.relay1.
The module name is configured in the Module name parameter in the Hardware / Extenders menu.
Outputs
- relay1 – relay output 1
- relay2 – relay output 2
- led_secured – red LED indicator at the panel
Inputs
- input1 – digital input 1
- input2 – digital input 2
- tamper – tamper switch (if installed)
Wiegand Module
The input is addressed as follows: <module_name>.<input_name>, e.g. module2.tamper
The module name is configured in the Module name parameter in the Hardware / Extenders menu.
Outputs
- output1 – output LED OUT
Inputs
- input1 – vstup LED IN
- tamper – tamper switch (if installed)
2N® IP Base
Outputs
- output1 – digital output
- relay1 – relay output
- led_secured – red LED indicator at the panel
Inputs
- input1 – digital input on basic unit
- tamper – tamper switch