3.2 Default Reset

Factory Default Reset

In some cases, it may be useful to reset the 2N® SIP Speaker Horn factory default values using the RESET switch on the back panel. Do so, for example, if 2N® SIP Speaker Horn ceases to respond due to, for example, incorrect LAN settings, LAN configuration changes, forgotten password and so on.

Reset Button

Located among the main unit connectors, the Reset button helps you reset the factory default values, restart the device, find the device IP address and switch the static/dynamic mode.

 

IP Address Finding

Follow the instructions below to identify the current IP address:

  • Press and hold the RESET button.
  • Wait until the red and green LEDs go on simultaneously on the device and the acoustic signal  can be heard (approx. 15–35 s).
  • Release the RESET button.
  • The device automatically announces the current IP address.

Note

  • The delay after pressing RESET till the first light and sound signalling is set to 15–35 s depending on the 2N IP intercom/answering unit model used.
    • 11 s is the valid value for 2N® SIP Speaker Horn.

Static IP Address Setting

Follow the instructions below to switch on the Static IP address mode (DHCP OFF):

  • Press and hold the RESET button.
  • Wait until the red and green LEDs go on simultaneously on the device and the acoustic signal  can be heard (approx. 15–35 s).
  • Wait until the red LED goes off and the acoustic signal  can be heard (approx. for another 3 s).
  • Release the RESET button.

The following network parameters will be set after restart:

  • IP address: 192.168.1.100
  • Network mask: 255.255.255.0
  • Default gateway: 192.168.1.1

 

Dynamic IP Address Setting

Follow the instructions below to switch on the Dynamic IP address mode (DCHP ON):

  • Press and hold the RESET button.
  • Wait until the red and green LEDs go on simultaneously on the device and the acoustic signal  can be heard (approx. 15–35 s).
  • Wait until the red LED goes off and the acoustic signal  can be heard (approx. for another 3 s).
  • Wait until the green LED goes off and the red LED goes on again and the acoustic signal  can be heard (approx. for another 3 s).
  • Release the RESET button.

 

Factory Reset

Follow the instructions below to reset the factory default values:

  • Press and hold the RESET button.
  • Wait until the red and green LEDs go on simultaneously and the acoustic signal  can be heard (approx. 15–35 s).
  • Wait until the red LED goes off and the acoustic signal  can be heard (approx. for another 3 s).
  • Wait until the green LED goes off and the red LED goes on again and the acoustic signal  can be heard (approx. for another 3 s).
  • Wait until the red LED goes off and the acoustic signal  can be heard (approx. for another 3 s). 
  • Release the RESET button.

Caution

  • In case of resetting the factory default settings on a device with a version of firmware 2.18 or higher it is necessary to reprogram the
    2N® Security Relay using the instructions from section 2.4.

Device Restart

Press the RESET button shortly (< 1 s) to restart the system without changing configuration. 

Note

  • The time interval between the short press of RESET and reconnection after restart is 13 s for 2N® SIP Speaker Horn.