3.2 Default Reset

Factory Default

The following factory default parameters are available:

Parameter

Default

DHCP

Off

IP address

192.168.1.100

Mask

255.255.255.0

Default gateway

192.168.1.1

User name

Admin

Password

2n

Factory Default Reset

In some cases, it may be useful to reset the 2N® SIP Speaker, Wall Mounted factory default values using the RESET switch on the back panel. Do so, for example, if 
2N® SIP Speaker, Wall Mounted ceases to respond due to, for example, incorrect LAN settings, LAN configuration changes, forgotten password and so on.

 

Factory Default Reset with Static IP Address

  1. Move the switch to the position RESET. Do not disconnect the device from the power supply while resetting.

    Reset with Static IP Address

  2. Wait until you can hear a beep (for approx. 18 s).
  3. Now move the RESET switch to the opposite position.

Device Restarting

Press the RESET button shortly (< 1 s) to restart the system without changing configuration.

Note

  • Časový interval od krátkého stisku tlačítka RESET po znovu připojení zařízení do sítě po proběhlém restartu trvá pro 2N® SIP Speaker do 14 s.