2.2.2 Mounting Box Installation

Mounting Box Installation



 
 


 
 


 

Make a hole of the size of 352 (h) x 167 (w) x 45 (d) mm for the mounting box installation. It is supposed that all the required cables have been carried into the hole. The recommended length of the accessible cables is 35 cm. Remove the selected mounting box blank for cabling. Thread the cables through the selected box hole and put the mounting box in the pre-prepared hole. Make sure that the mounting box hole is deep enough and that the box edges are aligned with the wall surface. If the hole is convenient, anchor the box using screws and dowels (1).

Insert the enclosed detents in the riveting nuts. Make sure that the tops of the detents direct towards the box center against each other. The detent with 2 handles is intended exclusively for the box bottom installation. Fit the detents with screws (2).

If the position of the detents seems to be too deep, untighten the screw to remove the detent fixture (3), insert a levelling key in the levelling mechanism grooves and turn it to adjust the required level (4). The levelling mechanism allows for a shift of up to 8 mm in height. 

After levelling re-anchor the fixture with a screw (5).

Use a levelling key to check the proper height of detent embedding to make sure that the key is aligned with the mounting box edge and also touches the detent surface (6).

Put the brackets to the left and right sides of the bottom detent handle (7A) and fit their positions using screws (7B).

Now the mounting box installation is complete (8).