4.6 Rescue Process Activation/End
Rescue Process Activation
Set parameter 992 (rescue password) to activate the rescue process. If an alarm call is set up, the yellow LED keeps shining on the audio unit after the call end to indicate the rescue process activation.
Rescue Process End
Call the CU (9 for administration – 2 for rescue end – enter password – press *) to deactivate the rescue process.
The audio unit announces "Rescue process ended" when the rescue process is completed.
Event after Rescue End
An event can be made when the rescue process has been ended. 2N® LiftIP supports operational calls only.
- Operational call – the call is set up to the number set in parameters 081–088 (operational call) and transmitted via CPC Antenna, CPC KONE or P100.
Set the parameters via the Service Tool (Events – Button stuck).
Parameter 990
From version 2.5.0 up, you can set operational calls (Audio error, Audio fixed) via parameter 990. Refer to Subs. 3.2 (Table of Parameters) for details.
Caution
- If set via parameter 990 and the Event menu (script), the operational call will be set up twice.