3.2 Default Reset

Factory Default

The following factory default parameters are available:

Parameter

Default

DHCP

Off

IP address

192.168.1.100

Mask

255.255.255.0

Default gateway

192.168.1.1

User name

Admin

Password

2n

Factory Default Reset

In some cases, it may be useful to reset the 2N® SIP Audio Converter  factory default values using the RESET button on the front panel. Do so, for example, if 
2N® SIP Audio Converter ceases to respond due to, for example, incorrect LAN settings, LAN configuration changes, forgotten password and so on.

 

Factory Default Reset with Static IP Address

  1. Use a thin rigid tool (toothpick or paperclip) to press the RESET button on the front panel. Do not disconnect the device from the power supply while resetting.

    Reset with Static IP Address

  2. Keep the RESET button pressed until the RDY/ACT LED stops flashing red and you can hear a beep (for approx. 18 s).
  3. Now release the RESET button.

Factory Default Reset with DHCP Client ON

  1. Use a thin rigid tool (toothpick or paperclip) to press the RESET button on the front panel and push the volume button at the same. Do not disconnect the device from the power supply while resetting.

    Reset with DHCP ON

  2. Keep the RESET and volume button pressed until the RDY/ACT LED stops flashing red and you can hear a beep (for approx. 18 s).
  3. Now release both the buttons.