5.9 Services / Signaling

The Signaling folder is used for battery check activation and 2N® EasyGate IP connection to a mobile network. 


  • Relay Function – define whether and when the relay is activated (closed).
    • Inactive – the relay is not activated in the case of power/wireless network failure.
    • Power Failure – the relay is activated in the case of power failure (in approx. 120 s).
    • Wireless Network Failure – the relay is activated in the case of wireless network disconnection (in approx. 120 s).
    • Power or Wireless Network Failure – the relay is activated in the case of power/wireless network failure (in approx. 120 s).
  • Relay Inversion – inverted relay activation logic. If the relay is inverted, the contact relay opens whenever the above mentioned events are generated (default: Not Inverted).
  • Relay State –  relay state depending on the relay function. The values are not closed/closed.
  • FXS Line Break Function – define whether and when the FXS line gets disconnected.
    • Disabled – the FXS line is not disconnected in the case of power/wireless network failure.
    • Power Failure – the FXS line is disconnected in the case of power failure (in approx. 120 s).
    • Wireless Network Failure – the FXS line is disconnected in the case of wireless network disconnection (in approx. 30 s).
    • Power or Wireless Network Failure – the FXS line is disconnected in the case of power/wireless network failure (in approx. 120 s).
  • FXS Line Break State – state of the relay. The values are active/inactive.