5.5.10 Lift Control


To control the floor lift access, connect the AXIS A9188 relay module to the 2N IP intercom (2N IP Style, 2N IP Verso2N IP Force2N IP Safety, 2N IP Vario). Up to 8 relay modules can be connected to one 2N IP intercom, each of which can control up to 8 floors, which makes a total of 64.

Relay Modules



  • Switch-On Duration – set the relay module activation time (range of 1 – 600 s).



  • Enabled – display the activation/deactivation of the AXIS A9188 module used for lift control for up to 8 floors.
  • IP Address – AXIS A9188 IP address.
  • State – display the state of the connected AXIS A9188 module (Error/Access denied/Ready/Offline).
  • Serial Number – AXIS A9188 serial number.



  • Username – external device authentication username. The parameter is only mandatory if the external device requests authentication.
  • Password – external device (WEB relay, etc.) authentication password. The parameter is only mandatory if the external device requests authentication. 

Caution

  •  You just need one authentication username and password for all the modules.


Floors



  • Floor Name – set the floor name.
  • Public Access – activate permanent floor access without any authentication.
  • Profile – select one or more time profiles to be applied. Set the time profiles in the Directory / Time Profiles section.
    •  mark the selection from predefined profiles or manual setting of a time profile for the given element.
    •  set a time profile for the given element. 

       

Tip

Certificate generation for AXIS A9188

  1. Retrieve the AXIS A9188 relay module in the LAN using AXIS IP Utility.
  2. Enter the root/root login.
  3. Select Preferences / Additional device configuration in the menu.
  4. A new device configuration window gets displayed.
  5. Select System Options / Security / Certificates.
  6. Click Create self-signed certificate to create a certificate.
  7. Complete all the required fields and click OK for confirmation.
  8. Go to System Options / Security / HTTPS.
  9. Select the certificate in a pop-up menu and press Save to save it.
  10. Move to the 2N IP intercom web interface, Hardware / Lift Control. Enter the login data and the relay module IP address.
  11. READY gets displayed at the relay module if the connection has been successful.