5.5.10 Lift Control


To control the floor lift access, connect the AXIS A9188 relay module to the 2N IP intercom (2N® IP Style, 2N® IP Verso2N® IP Force2N® IP Safety, 2N® IP Vario). Up to 8 relay modules can be connected to one 2N IP intercom, each of which can control up to 8 floors, which makes a total of 64.

Relay Modules



  • Switch-On Duration – set the relay module activation time (range of 1 – 600 s).



  • Enabled – display the activation/deactivation of the AXIS A9188 module used for lift control for up to 8 floors.
  • IP Address – AXIS A9188 IP address.
  • State – display the state of the connected AXIS A9188 module (Error/Access denied/Ready/Offline).
  • Serial Number – AXIS A9188 serial number.



  • Username – external device authentication username. The parameter is only mandatory if the external device requests authentication.
  • Password – external device (WEB relay, etc.) authentication password. The parameter is only mandatory if the external device requests authentication. 

Caution

  •  You just need one authentication username and password for all the modules.


Floors



  • Floor Name – set the floor name.
  • Public Access – activate permanent floor access without any authentication.
  • Profile – select one or more time profiles to be applied. Set the time profiles in the Directory / Time Profiles section.
    •  mark the selection from predefined profiles or manual setting of a time profile for the given element.
    •  set a time profile for the given element. 

       

Tip

Certificate generation for AXIS A9188

  1. Retrieve the AXIS A9188 relay module in the LAN using AXIS IP Utility.
  2. Enter the root/root login.
  3. Select Preferences / Additional device configuration in the menu.
  4. A new device configuration window gets displayed.
  5. Select System Options / Security / Certificates.
  6. Click Create self-signed certificate to create a certificate.
  7. Complete all the required fields and click OK for confirmation.
  8. Go to System Options / Security / HTTPS.
  9. Select the certificate in a pop-up menu and press Save to save it.
  10. Move to the 2N IP intercom web interface, Hardware / Lift Control. Enter the login data and the relay module IP address.
  11. READY gets displayed at the relay module if the connection has been successful.