5.6.7 SMS

The SMS folder helps you enable and set programming of a connected 2N Lift1 lift intercom using SMS. Having received an SMS with the programming request, 2N EasyGate IP establishes connection with 2N Lift1 via a phone line and program it using the CPC protocol.

Caution

  • If a value is changed in a setting, you have to press Save changes before performing further actions.
  • Enable Service – enable/disable 2N Lift1 programming via SMS. If disabled, 2N EasyGate IP does not respond to the SMS (sends no response).
  • Pre-Authorization – verification of the EGIP / LIFT1 password before the SMS request is processed. The EGIP password matches the 2N EasyGate IP password (serial number / security code). The default LIFT1 pre-authorization password is 12345.
    • Strong – verify EGIP password before SMS request processing.
    • Weak (default value) – verify LIFT1 password before SMS request processing.
    • None – no password verification before SMS request processing.
  • Last Response
    • None – nothing is set upon the start via SMS or Configuration, see below.
    • Successful – communication OK.
    • Communication Error2N Lift1 communication error.
    • Invalid Parameters – a wrong parameter/value has been entered.
  • Configuration – configure 2N Lift1 as via SMS by entering the required parameters (e.g. by entering "011=xxxxxxxxxxxxx 012=xxxxxxxxxxxx 111=2 112=4" you make configuration possible even if the service is disabled, enabled applies to incoming SMS only).

Press Upload configuration to upload the settings to 2N Lift1.

Press Save changes to save the changes.

SMS CommandSMS Format
Configuration (CNF)L1 CNF <pwd> <p1>=<v1> [<p2>=<v2> [<p3>=<v3> …]]
Factory default reset (DEF)L1 DEF <pwd>
Profile selection (SET)L1 SET <pwd> <profile>
Device restart (RST)L1 RST <pwd>
Device information (INF)L1 INF <pwd>
Response (OK / ERR)L1 [OK|ERR] msg=<msg> cmd=<cmd> seq=<seq>

The example below programs 2N Lift1 ALARM button memory 1 and 2 for the specified phone numbers.

  • SMS format: L1 CNF 12345 011=00420222222222 012=00420111111111
  • The parameters must be separated with a space.
Description
<pwd>authorization password
<profile>profile number (0 - 19)
<pn>parameter number
<vn>numeric value or text value in brackets
<msg>detailed description

Successful
Busy
Invalid password (EGIP)
Invalid password (LIFT1)
Invalid parameters
Invalid syntax
Communication error
Does not respond
<cmd>the command to which it responds (CNF,DEF,SET,RST,INF)
<seq>sequence counter
<num>numeric value

Example of parameter settings:

  • L1 CNF <pwd> 100=0
Feedbacks for Commands
L1 CNF OKSetting ok

L1 DEF OK
L1 SET OK
L1 RST OK
L1 ERR Invalid MessagePrefix L1 invalid
L1 ERR Unknown Command Wrong command other than CNF, DEF, SET and RST
L1 ERR Invalid PasswordInvalid password
L1 ERR Invalid ParametersInvalid CNF and SET parameters
L1 ERR Invalid Syntax

Invalid characters (spaces, equal signs, etc.)

L1 ERR Does not Respond



  • 2N Lift1 fails to hook off within 60s ringing timeout.
  • 2N Lift1 picks up but fails to respond to the CPC programming command.
  • 2N Lift1 hangs up during programming.
  • 2N Lift1 fails to respond to the communication commands (WRITE_START, WRITE_CONFIRM, CRC_REQUEST).
L1 INF sn="<s/n>" hw="<version no.>" cust="<n>" app="<fw no.>" bl="<bl no.>" vm="<voice menu>"

Setting information:

  • sn – serial number
  • hw – hardware type
  • cust – user profile (1-19)
  • app – firmware version
  • bl – bootloader version
  • vm – voice menu

Caution

  • Multiple commands cannot be combined in a single SMS.
  • The maximum SMS length is 140–160 characters; if a setting outside the value range is requested or an error occurs in the SMS, the setting change will not be performed.