5.6.7 SMS
The SMS folder helps you enable and set programming of a connected 2N Lift1 lift intercom using SMS. Having received an SMS with the programming request, 2N EasyGate IP establishes connection with 2N Lift1 via a phone line and program it using the CPC protocol.
Caution
- If a value is changed in a setting, you have to press Save changes before performing further actions.
- Enable Service – enable/disable 2N Lift1 programming via SMS. If disabled, 2N EasyGate IP does not respond to the SMS (sends no response).
- Pre-Authorization – verification of the EGIP / LIFT1 password before the SMS request is processed. The EGIP password matches the 2N EasyGate IP password (serial number / security code). The default LIFT1 pre-authorization password is 12345.
- Strong – verify EGIP password before SMS request processing.
- Weak (default value) – verify LIFT1 password before SMS request processing.
- None – no password verification before SMS request processing.
- Last Response
- None – nothing is set upon the start via SMS or Configuration, see below.
- Successful – communication OK.
- Communication Error – 2N Lift1 communication error.
- Invalid Parameters – a wrong parameter/value has been entered.
- Configuration – configure 2N Lift1 as via SMS by entering the required parameters (e.g. by entering "011=xxxxxxxxxxxxx 012=xxxxxxxxxxxx 111=2 112=4" you make configuration possible even if the service is disabled, enabled applies to incoming SMS only).
Press Upload configuration to upload the settings to 2N Lift1.
Press Save changes to save the changes.
SMS Command | SMS Format |
---|---|
Configuration (CNF) | L1 CNF <pwd> <p1>=<v1> [<p2>=<v2> [<p3>=<v3> …]] |
Factory default reset (DEF) | L1 DEF <pwd> |
Profile selection (SET) | L1 SET <pwd> <profile> |
Device restart (RST) | L1 RST <pwd> |
Device information (INF) | L1 INF <pwd> |
Response (OK / ERR) | L1 [OK|ERR] msg=<msg> cmd=<cmd> seq=<seq> |
The example below programs 2N Lift1 ALARM button memory 1 and 2 for the specified phone numbers.
- SMS format: L1 CNF 12345 011=00420222222222 012=00420111111111
- The parameters must be separated with a space.
Description | |
---|---|
<pwd> | authorization password |
<profile> | profile number (0 - 19) |
<pn> | parameter number |
<vn> | numeric value or text value in brackets |
<msg> | detailed description |
Successful | |
Busy | |
Invalid password (EGIP) | |
Invalid password (LIFT1) | |
Invalid parameters | |
Invalid syntax | |
Communication error | |
Does not respond | |
<cmd> | the command to which it responds (CNF,DEF,SET,RST,INF) |
<seq> | sequence counter |
<num> | numeric value |
Example of parameter settings:
- L1 CNF <pwd> 100=0
Feedbacks for Commands | |
---|---|
L1 CNF OK | Setting ok |
L1 DEF OK | |
L1 SET OK | |
L1 RST OK | |
L1 ERR Invalid Message | Prefix L1 invalid |
L1 ERR Unknown Command | Wrong command other than CNF, DEF, SET and RST |
L1 ERR Invalid Password | Invalid password |
L1 ERR Invalid Parameters | Invalid CNF and SET parameters |
L1 ERR Invalid Syntax | Invalid characters (spaces, equal signs, etc.) |
L1 ERR Does not Respond |
|
L1 INF sn="<s/n>" hw="<version no.>" cust="<n>" app="<fw no.>" bl="<bl no.>" vm="<voice menu>" | Setting information:
|
Caution
- Multiple commands cannot be combined in a single SMS.
- The maximum SMS length is 140–160 characters; if a setting outside the value range is requested or an error occurs in the SMS, the setting change will not be performed.